  • Built-in audible alarm.
  • New, easy to read LCD display with 30 day summary in calendar format.
  • Up to 15,900 recordings – Enough memory for 66 days at 6 minute logging.
  • Auto-pause function – unplugging the external probe automatically suspends alarm & statistics processing.
  • Record inspections at the push of a button.
  • Interchangeable External Probe with high quality gold plated connector.
  • Comprehensive customisation options including alarm settings, sample interval and trip duration

The TRED30-16R supersedes the existing TRED30-7 model.

The LogTag® TRED30-16R Temperature Recorder measures and stores up to 15,900 temperature readings over a -40°C to +99°C (-40°F to +210°F) measurement range from an External Probe.

The display is designed to show ‘at a glance’ if temperature excursions have occurred during the current day and up to the previous 29 days. The display also shows the current temperature reading, the current time, recording status and battery status.

The alarm is trigged if temperature readings are outside pre-set alarm limits. The status indicator changes from a ✔ to a X and, if configured, the audible alarm will sound. The day marker will also appear if not already present. The alarm status indicator and audible alarm can be easily cleared, but the day marker remains to ensure a visible record of excursions is shown on the display. A simplified alarm clearance, stop & start procedure is available as an option.

Details of any excursions in the preceding 30 days can be checked directly by inspecting the statistics history on the recorder’s display or in more detail by downloading the logged data via a standard LogTag® Interface cradle to LogTag® Analyzer operating software.

Additional information

Additional information

Weight 0.04 kg
Specifications

Specifications

Models TRED30-16R
External Temperature Sensor Measurement Range -40°C ~ +99°C  (-40°F ~ +210°F)
Operating Temperature Range -30°C ~ +60°C  (-22°F ~ +140°F)
Storage Temperature Range -10°C ~ +40°C  (-14°F ~ +104°F)
Rated Temperature Reading Accuracy Better than ±0.5°C ( ±0.9°F) for -20°C to +40°C (-4°F to +104°F), typically ±0.3°C (0.6°F).
Better than ±0.8°C ( ±1.4°F) for -40°C to -20°C (-40°F to -4°F), typically ±0.5°C (0.9°F).
Better than ±0.8°C ( ±1.4°F) for +40°C to +70°C (+104°F to +158°F), typically ±0.7°C (1.3°F)
Better than ±1.2°C ( ±2.2°F) for +70°C to +99°C (+158°F to +210°F), typically ±1°C (1.8°F).
Actual performance is typically much better than the rated values. Please see the Rated Absolute Accuracy chart above.
Accuracy figures can be improved by recalibration.
Rated Temperature Reading Resolution 0.1°C (0.2°F) for measurements -40°C to +50°C (-40°F to +122°F)
0.2°C (0.4°F) for measurements +50°C to +70°C (+122°F to +158°F)
0.3°C (0.5°F) for measurements +70°C to +80°C (+158°F to +176°F)
0.4°C-0.6°C (0.7°F to 1°F) for measurements +80°C to +99°C (+176°F to +210°F)
Please see the Rated Native Resolution chart above. LogTag Analyzer® currently displays to one decimal place of °C or °F. The native resolution is what is stored in the LogTag®.
Recording Capacity 15,905 temperature readings. 66 days @ 6min logging.
Day summary statistics memory (for display on LCD): up for 30 days of Max/Min/duration and alarm trigger statistics.
Sampling Frequency Configurable from 30 seconds to hourly.
Sensor Reaction Time Typically less than 2 minutes (T90) in moving air (1m/s) for ST100T,ST100H & ST100S types.
Logging Start Options Push button start or specific date & time. Optional start delay of up to 18hours.
Recording Indication State indicator “REC”
Download Time Typically less than 10 seconds for full memory (15,905 readings), depending on computer or readout device used.
Environmental IP61 (when vertically mounted or hung).
Power Source 3V CR2032 (LiMnO2) coin cell battery, user replaceable
Battery Life Typically 1 year of operation.
NOTE: Typical battery life assumes 6 minute logging, day statistics are reviewed on the display no more than once daily for no longer than 30 seconds each time.
Download data monthly.
NOTE: Continual activation of the audible alarm will reduce the working life of the battery. When an alarm is triggered, the alarm should be cleared and reset as soon as possible.
Size 93mm(H)x54.5mm(W)x8.6mm(T)
Weight 41grams without External Probe
Case Material Polycarbonate
Standard External Probe Cable Lengths Standard: 1.5m (4’11”).
Extended: 3 m (9’10”) (recommended maximum).
Remote External Probe Type PTFE (FDA food contact rated) coaxial.
Accessories

Accessories

External Temperature Probes

The LogTag® TRED30-16R requires an external External Temperature Probe to function correctly. LogTag® have a range of FDA food rated high quality ST100 probes for you to select one best suited for your application.
Click here for more information

Interface Cradle

LogTags® unique interface cradle design provides rapid and reliable data transfer to LogTag® Analyzer software in a matter of seconds. By far the fastest in its class.
Click here for Interface Cradle details.

Glycol buffer

The LogTag® Glycol Buffer is used where vaccines need to be monitored during storage or transport. It mirrors the temperature environment inside a vaccine vial.
Click here for Glycol Buffer details.

Wall Mount Bracket

The LogTag® Wall Mount Bracket provides an easy and tidy solution to mounting a LogTag® on a wall, door or vertical surface while still allowing easy removal of the LogTag® for inspection or download.
Click here for Wall Mount Bracket details.

Support / Downloads

Support / Downloads

TRED30-16R Quickstart Guide

Learn how to quickly operate the TRED30-16R device following the step-by-step instructions.

Click here download the TRED30-16R Quickstart Guide.

FAQ/Troubleshooting

Get answers to your questions by contacting us.

Click here to view the Contact Page.

LogTag® Analyzer Software

Get access to our free software which you can use with the TRED30-16R device.

Click here to enquire about the latest version of LogTag® Analyzer.